Follow us :

  • With an air push button the solutions arequite simple most of the time. 1. If the button is hard to press or comesback too slowly to its initial position, there may be too much air accumulatedwithin the hose. - To correct the problem, locate thetransparent hose and with a thin pin, poke one or two holes through it to letthe air out. (This will not harm your system in any way).- Verify that the hos...

  • Toverify that the air-heating element is functioning normally, turn on yoursystem and let it run. After approximately 5 minutes, touch the air hose thatis connected to your blower. It should feel hot. 1. Ifthe hose does not feel hot, contact your distributor who will guide you throughthe procedure to get your blower changed. 2. Ifthe air hose feels hot, the blower is not defective. The cool sensat...

  • Checkthe HP of the motor for GPM. Determine how many jets are in the spa. You shouldhave 10-12 GPM per jet.Checkretainer ring for the following:1. Retainer ring does nothave Teflon tape around thread or not enough.2. Retainer ring is notthreaded in all the way. You may need to extend length with 1″ coupler.3. Retainer ring and 1″ pipeis not glued in all the way so that it is flush with...